A solar array produces 7.8 kWh instead of 11.5 kWh. Why?

  • Diagnose the Failure
  • Renewable Energy
  • intermediate
Competency Fault diagnosis primary Evidence interpretation supporting Quantitative reasoning supporting

What you should take away: Compare measured yield with the design yield and use string-level current data to distinguish shading or soiling from inverter or battery limitations.

The situation

What is happening

A 2.7 kWp off-grid array is designed to produce about 11.5 kWh/day at 5 peak sun hours and 15 % derating. On a clear day it produces 7.8 kWh, about 32 % below expectation. The inverter is not clipping, the battery is accepting charge, and one string shows a lower current than the others. What is the most plausible diagnosis?

Given

Scenario values with units
QuantityValueUnitNote
Array rating 2.7 kWp Six 450 W panels.
Design yield 11.5 kWh/day At 5 peak sun hours and 15 % derating.
Measured yield 7.8 kWh/day About 32 % below design.
Inverter status No clipping - Output is below the inverter limit.
String currents One low - The other strings are normal.

Assumptions this challenge makes

  • The irradiance and temperature on the test day are close to the design conditions.
  • The battery is accepting charge and is not limiting the array.
  • The inverter is operating and is not clipping or derating.

Your call

Your answer

Which diagnosis is most plausible?

What this challenge does not establish

  • The design yield is a screening estimate; actual irradiance, temperature and spectrum vary.
  • The diagnosis assumes the string currents were measured at the same irradiance and temperature.
  • The calculation does not test modules, bypass diodes or wiring; those require electrical measurements.
  • Shading can be seasonal or time-of-day dependent, so a single measurement may not capture the full loss.