EngiMetric Arena / Design Challenge

Size an infiltration trench for a 1,200 m2 car park

  • Design Challenge
  • Environmental
  • intermediate
Competency Design and sizing primary Quantitative reasoning supporting Systems and balances supporting

What you should take away: Convert a catchment runoff volume into the physical length of a storage trench, accounting for the void space in the aggregate.

The situation

What is happening

A 1,200 m2 car park drains to an infiltration trench. The design storm is 32 mm, the runoff coefficient is 0.9, the trench is 1.0 m wide and 1.2 m deep, and the aggregate void ratio is 35 %. Size the trench length required to store the runoff.

Given

Scenario values with units
QuantityValueUnitNote
Catchment area 1 200 m2 Car park draining to the trench.
Design rainfall 32 mm Design storm depth.
Runoff coefficient 0.9 - Paved surface.
Trench width 1.0 m Fixed by the site strip.
Trench depth 1.2 m Fixed by the invert and cover.
Void ratio 35 % Storage voids in the aggregate.

Assumptions this challenge makes

  • The trench is rectangular with vertical sides and a flat base.
  • The design storm volume is stored before infiltration is credited; infiltration only affects drain-down.
  • The void ratio applies uniformly to the aggregate fill.

Your call

Your answer

Enter the trench length in metres. The width and depth are fixed by the site.

What this challenge does not establish

  • Infiltration during the storm is not credited; the full runoff volume is stored. This is conservative.
  • The trench is treated as a clean rectangular void with uniform aggregate; clogging and sediment build-up reduce storage over time.
  • Groundwater level, separation to the water table and infiltration-rate testing are not assessed.
  • The design storm is a single depth, not a full rainfall hyetograph or a site-specific return-period analysis.